

Services

Manual J Load Calculation
Manual D Duct Design
Manual S Equipment Selection
Florida Energy Calculations Residential/Commercial Permitting
Florida Energy Code Compliance
Blower Door Testing
Building & System Diagnostic
3d BIM Modeling (mechanical)
2d CAD Services (mechanical)
Projects
Residential Construction Commercial Construction
New Construction
Additions
Renovations
Remodels
Virtual Modeling & Coordination
Drafting Services
Compliance Testing
Failure Diagnostic
About
State licensed HVAC contractor with 30years of experience in coastal central Florida. FlaCom Services exists to provide clients with professional code compliance, HVAC calculation, design, and diagnostic services from a trained unbiased third party. Proudly serving the State of Florida Construction Industry
Service Areas
Sarasota / Bradenton
Siesta Key
Longboat Key
Casey Key
Manatee
Lakewood Ranch
Charlotte
​
Electronically Serving All Of Florida
Manual J Load Calculation
​
All heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated with ACCA Manual J calculation methodology. Based on actual internal and external building loads for the directional orientation of the building.
Manual D Duct Design
All duct systems serving all heating, cooling, and ventilation equipment shall be fabricated in accordance with ACCA Manual D methodologies. Duct materials and sizing shall be determined by ACCA Manual J requirements of each space, available static pressure, and total equivalent length.
​Manual S Equipment Selection
All heating and cooling equipment shall be selected based on loads calculated using ACCA Manual J methodology. Where the total capacity of the selected equipment is not less than the calculated total, but also not more than 1.15 greater than the total load.
Florida Energy Code Residential
​
Non-exempt residential buildings code compliance forms must be submitted to the local building official for a permit. R103.1.1.1.1-No license or registration is required to prepare compliance forms for single-family dwellings, duplexes and townhouses.
Residential & Commercial Permitting
Form R402-2020 Prescriptive
Form R405-2020 Performance
Energy Performance Level EPL Card
Envelope Leakage Test report
Duct Leakage Test report
C401.2.3 FBC Total Building
C401.2.2 FBC Prescriptive
C401.2.1 ASHRAE Energy Cost
C401.2.1 ASHRAE Prescriptive
Florida Energy Code Commercial
Non-exempt commercial and multi-family buildings compliance forms must be submitted to the local building official for a permit. C103.1.1.1.2-Completing compliance for commercial and multi-family buildings shall be in accordance with Section 481.229 or Section 471.003 Florida Statutes.
Blower Door Testing
​
Homes and multifamily buildings permitted AFTER July 1, 2017 will require mandatory air infiltration testing for compliance with Florida building code, Energy Conservation. Specializing in custom residential construction, contact us for testing services pricing and availability.
Building & System Diagnostic
Buildings and systems often do not perform as designed. High electrical consumption, poor indoor air quality and damage to construction is often the result of systems non functional. Contact us for on site data collection & analysis of problematic hvac or building envelope systems.
BIM Modeling (Mechanical)
Providing 3d mechanical modeling and ongoing coordination services for mechanical subcontractors. Models created from contract cad files and approved submittals. Specializing in high rise residential services, contact us for modeling services pricing and availability.

​

